Dust Collection Equipment / AWC System

AWC VENTILIATION SYSTEM

Dust Collection Equipment

The AWC modules will connect to a remote fan(s) sized for the specific installation. Each AWC module can filter from 32,000 to 48,000 CFM.

An exclusive “dual process” feature available with the AWC modules allows them to be used for both dry or wet applications using the same fan(s). During wet process applications the plenum will draw air directly though a set of low leakage dampers in the front of the clean air plenum, by-passing the cartridge filters to provide simple ventilation or air movement during wet processes.

During dry process operations producing dust, these dampers will close and an additional set of low leakage dampers inside the plenum will open to allow the air to flow through the baffled air inlets and then through the cartridge filters. The dampers are automatically controlled to allow only one set to be open at a time, depending on the type of operation being performed.

Several AWC modules may be connected side by side to provide dust collection volumes of over 1,000,000 CFM. All AWC modules are provided with an automatic reverse pulse filter purging system.

 

MODEL CART QTY CFM FILTER AREA A/F RATIO WIDTH DEPTH HEIGHT FAN SHIP WEIGHT
AWC-2 60 32000 14400 2.22:1 152 48 108 A/R 4,200
AWC-3 90 48000 21600 2.22:1 227 48 108 A/R 6,300